Fire Detection Systems
ITM-TD921
- Conventional Heat Detector
- Compatible with all the conventional fire alarm control panel
- Unpolarized wire input
- Wide range of operating voltages
- High precision electronic thermistor
- Built in microprocessor intelligent software
- Two LEDs blink standby, provide 360° visibility
- Insect-resistant screening
- Twist-on mounting base with tamper lock
- Remote Indicator LED can be connected
ITM-MC961
- Manual Call Point
- Compatible with all the conventional fire alarm
- control panel
- Can be reset by key
- 470 Ohm resistance
- Easy surface mounting Base included
ITM-SS992
- Sound Strobe
- Compatible with all the conventional fire alarm control panel
- Long light life up to 40000 flashed
- High sound level up to 100dB
ITM-CK10 SERIES
- Conventional Fire Alarm Panel
- Four, Eight, Sixteen Zone Style B (Class B)
- Initiating Device Circuits (IDCs), All zones
- accept two-wire smoke detectors and any normally-open contact devices
- Two Supervisory Input with DC12V output, ideal to connect security alarm devices
- Three General Alarm, Trouble and Supervisory, Form A Relay Output
- One, Two, Four Built-in Sound Output, Style Y
- (Class B) Notification Appliance (Signal)
- Circuits (NACs), NACs may be programmed
- Silence-able or Non-Silence-able.
- 3.0 amps of total system power
- Re-settableDC24V & Non-re-settable DC24V Output.
- Zone Input Short Circuit can be set to “Alarm” or “ Fault” mode
- RS485 Communication Port (optional)
- Automatic/Manual mode can be programmed
- Disable/Enable control per Zone (IDC) can be programmed
- Disable/Enable Sound Output(NACs) can be programmed
ITM-SH937
- Conventional Smoke & Heat Detector
- Compatible with all the conventional fire alarm control panel
- Unpolarized wire input
- Wide range of operating voltages
- Unique optical sensing chamber and High precision electronic thermistor
- Built in microprocessor intelligent software
- Two LEDs blink standby, provide 360° visibility
- Insect-resistant screening
- Twist-on mounting base with tamper lock
- Drift compensation and smoothing algorithms
- Remote Indicator LED can be connected
ITM-RP982
- Addressable Fire Alarm Repeater
- Microprocessor-controlled fire display panel connected to control panel
- Connected with a fire alarm control panel via a RS-48 bus.
- Executive standard: General Technical Conditions for Fire Indicating Panels (GB17429-1998)
- Display capacity: display the fire alarm messages of floors -10~90 and at most 99 fire alarm messages or feedback messages
- Wiring system: Four-wire system, power lines (+24V, GND) and RS485 signal lines (485A,485B)
- Operating environment: Indoor; temperature: -10~+50; Relative humidity: =95% (40,without condensation)
- Power supply: DC 24V ±20 % and Overall power consumption: <3W
- Contact capacity: Relay dry contacts, normally open or normally closed, capacity: 1.25A/DC30V (resistive load)