ITM-TD921

  • Conventional Heat Detector
  • Compatible with all the conventional fire alarm control panel
  • Unpolarized wire input
  • Wide range of operating voltages
  • High precision electronic thermistor
  • Built in microprocessor intelligent software
  • Two LEDs blink standby, provide 360° visibility
  • Insect-resistant screening
  • Twist-on mounting base with tamper lock
  • Remote Indicator LED can be connected

ITM-MC961

  • Manual Call Point
  • Compatible with all the conventional fire alarm
  • control panel
  • Can be reset by key
  • 470 Ohm resistance
  • Easy surface mounting Base included

ITM-SS992

  • Sound Strobe
  • Compatible with all the conventional fire alarm control panel
  • Long light life up to 40000 flashed
  • High sound level up to 100dB

ITM-CK10 SERIES

  • Conventional Fire Alarm Panel
  • Four, Eight, Sixteen Zone Style B (Class B)
  • Initiating Device Circuits (IDCs), All zones
  • accept two-wire smoke detectors and any normally-open contact devices
  • Two Supervisory Input with DC12V output, ideal to connect security alarm devices
  • Three General Alarm, Trouble and Supervisory, Form A Relay Output
  • One, Two, Four Built-in Sound Output, Style Y
  • (Class B) Notification Appliance (Signal)
  • Circuits (NACs), NACs may be programmed
  • Silence-able or Non-Silence-able.
  • 3.0 amps of total system power
  • Re-settableDC24V & Non-re-settable DC24V Output.
  • Zone Input Short Circuit can be set to “Alarm” or “ Fault” mode
  • RS485 Communication Port (optional)
  • Automatic/Manual mode can be programmed
  • Disable/Enable control per Zone (IDC) can be programmed
  • Disable/Enable Sound Output(NACs) can be programmed

ITM-SH937

  • Conventional Smoke & Heat Detector
  • Compatible with all the conventional fire alarm control panel
  • Unpolarized wire input
  • Wide range of operating voltages
  • Unique optical sensing chamber and High precision electronic thermistor
  • Built in microprocessor intelligent software
  • Two LEDs blink standby, provide 360° visibility
  • Insect-resistant screening
  • Twist-on mounting base with tamper lock
  • Drift compensation and smoothing algorithms
  • Remote Indicator LED can be connected

ITM-RP982

  • Addressable Fire Alarm Repeater
  • Microprocessor-controlled fire display panel connected to control panel
  • Connected with a fire alarm control panel via a RS-48 bus.
  • Executive standard: General Technical Conditions for Fire Indicating Panels (GB17429-1998)
  • Display capacity: display the fire alarm messages of floors -10~90 and at most 99 fire alarm messages or feedback messages
  • Wiring system: Four-wire system, power lines (+24V, GND) and RS485 signal lines (485A,485B)
  • Operating environment: Indoor; temperature: -10~+50; Relative humidity: =95% (40,without condensation)
  • Power supply: DC 24V ±20 % and Overall power consumption: <3W
  • Contact capacity: Relay dry contacts, normally open or normally closed, capacity: 1.25A/DC30V (resistive load)